As was alluded to earlier by Corey, it looks like the CPSs on BSC2 started glitching this morning and caused the ISI to trip, breaking several locks. Attached plot shows several hours around the locklosses this morning. The windows where the ST1 WD was at state 4 are when the WD tripped. The long fuzzy period on the left of the CPS plots are the earthquake this morning, only ST1 H3 & V3. It looks like the CPS started glitching some time after the earthquake. I went out, pulled and reconnected the power on the satellite racks on the chamber. I've had a striptool running of the CPS since power-cycling and it looks like the glitching has stopped. Given the glitches start before getting bad enough to trip the ISI, maybe we can come up with some of diagnosing before this becomes a problem, so we at least know what we have to fix. I don't know what that would be though. We could at least get longer trends (an hour or two) of CPS if a "mysterious" ISI trip is suspected of causing a lock loss.
Do the corner 3 Stage 2 sensors show any of this glitchiness?
Yes Richard, see my later plots.