Modification of RF cabling for 72 MHz WFSs

WP 7075

To further proceed with the 72 MHz WFS (Wave Front Sensor)s (37042), today I made the hardware changes (mostly cabling), as summarized below, while the interferometer was in a violin-mode-damping state.

I am going to leave the hardware configuration as it is. If this new setup doesn't cause extra noise in the interferometer, they will stay semi-permanently.

Here is a summary of the new configuration:

[The modifications]

Images attached to this report
Comments related to this report
kiwamu.izumi@LIGO.ORG - 10:45, Friday 14 July 2017 (37524)

Later, Jenne pointed out that the dark offset should have been readjusted. So we re-adjusted the dark offset. As a result, the -1 dB gain I originally placed turned out to be inaccurate. I set it to 2 dB in order to get roughly 550 counts at the normalized in-phase output when the DRMI is locked with the arm at a off resonance point. The RF phase is also adjusted accordingly.

sheila.dwyer@LIGO.ORG - 18:45, Tuesday 18 July 2017 (37601)

It seems like since this work there has been excess low frequency noise in the RF9 AM stabilization control signal. The attachment shows the difference.