Reports until 21:01, Friday 14 July 2017
H1 ISC (ISC)
thomas.vo@LIGO.ORG - posted 21:01, Friday 14 July 2017 (37536)
More Beam Position Work

Jenne D. Thomas V.

After Robert finished his PEM injections, we wanted to try to change the pointing into the interferometer after IMC using the IM1 and IM3 to put IM4 Trans QPD back to the pre-EQ location, this seemed to help the range a bit as well as increase the power recycling gain.

Since we were convinced the pointing was satisfactory, we began to try to optimize the spot locations using the reverse A2L procedure using the June 18th data as a good reference.  However, this really screwed up the sensitivity so we're leaving the SOFT loop offsets back at zero.

So in the end, there's a bit of change to the input pointing, spot positions remain unchanged, A2L gains remain unchanged.