Reports until 21:25, Monday 17 July 2017
H1 ISC
corey.gray@LIGO.ORG - posted 21:25, Monday 17 July 2017 - last comment - 23:40, Monday 17 July 2017(37572)
Stuck With ALSy Problems

ALSx is fine.

ALSy has not been able to stay locked in a 00.  I've tried tweaking on the ETMy to no avail.  I am currently on LOCKED_NO_SLOW_NO_WFS, and wanting to reduce WFS & CAM signals for the Y-arm, but it simply doesn't stay locked long enough for me to relieve the large output values.  

Comments related to this report
corey.gray@LIGO.ORG - 23:40, Monday 17 July 2017 (37573)

Problem Resolved:  I was looking elsewhere and Thomas V suggested a Clear History for ALSy & this did the trick.