Reports until 17:37, Wednesday 08 August 2012
H2 CDS
david.barker@LIGO.ORG - posted 17:37, Wednesday 08 August 2012 - last comment - 18:04, Wednesday 08 August 2012(3762)
many front end restarts

After syncing up the userapps/release SVN files on h2build I rebuilt most of the H2 models during Tue maintanance and restarted most models.

A problem with the folding mirror sus models was resolved with a new BSFM_MASTER file. We will install new h2susfmy code tomorrow.

New Dolphin and RFM IPC between ISI and SUS was installed today by Vincent, replacing the EPICS comms link.

New slow channels for PEM (DUST monitor) and HWS were added to the H2 frame.

h2iscey model was changed for ISC -> ALS name change. Please see Bram's alog for details.

Comments related to this report
bram.slagmolen@LIGO.ORG - 18:04, Wednesday 08 August 2012 (3763)

That will be Jamie's entry 3759