Displaying report 1-1 of 1.
Reports until 16:08, Thursday 20 July 2017
H1 ISC
thomas.vo@LIGO.ORG - posted 16:08, Thursday 20 July 2017 (37660)
Mystery Noise 15-80 Hz Not Length DoFs

Attached are plots (Pictures 1&2) of MICH, PRCL, SRCL, and DARM spectra (one plot is zoomed into 10-100 Hz):

References are before the earthquake (06/23/17 03:00:00)

Non-References are after the earthquake (07/20/17 03:00:00)

Seems like no real differences except for MICH so I made a TF between it and DARM  just to make sure (Picture 3)

it doesn't look like these DoFs are the root of our problem.

 

Non-image files attached to this report