J. Kissel Took some earthquake time to measure as much SUS as I could. 4 Chains x 6 DOFs in 1.5 hours? Not bad! The ITMs are clear of rubbing. I'll post more detailed plots and compare against old data and model tomorrow. I attach a few choice DTT screenshots of the current measurement (where the reference is some random reference that shouldn't be treated as cannon, but in most cases is indicative of goodness) to whet your appetite. Data files live here: /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGM0/Data/ 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_L_0p01to50Hz.xml 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_P_0p01to50Hz.xml 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_R_0p01to50Hz.xml 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_T_0p01to50Hz.xml 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_V_0p01to50Hz.xml 2017-07-20_2320_H1SUSITMX_M0_WhiteNoise_Y_0p01to50Hz.xml /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/SAGR0/Data/ 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_L_0p01to50Hz.xml 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_P_0p01to50Hz.xml 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_R_0p01to50Hz.xml 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_T_0p01to50Hz.xml 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_V_0p01to50Hz.xml 2017-07-21_0016_H1SUSITMX_R0_WhiteNoise_Y_0p01to50Hz.xml /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGM0/Data/ 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_L_0p02to50Hz.xml 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_P_0p02to50Hz.xml 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_R_0p02to50Hz.xml 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_T_0p02to50Hz.xml 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_V_0p02to50Hz.xml 2017-07-20_2320_H1SUSITMY_M0_Mono_WhiteNoise_Y_0p02to50Hz.xml /ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/SAGR0/Data/ 2017-07-20_2358_H1SUSITMY_R0_L_WhiteNoise_0p01to50Hz.xml 2017-07-20_2358_H1SUSITMY_R0_P_WhiteNoise_0p01to50Hz.xml 2017-07-20_2358_H1SUSITMY_R0_R_WhiteNoise_0p01to50Hz.xml 2017-07-20_2358_H1SUSITMY_R0_T_WhiteNoise_0p01to50Hz.xml 2017-07-20_2358_H1SUSITMY_R0_V_WhiteNoise_0p01to50Hz.xml 2017-07-20_2358_H1SUSITMY_R0_Y_WhiteNoise_0p01to50Hz.xml Notes: Measurements were run with all nominal offsets on. Made sure to remove TEST bank P and Y gains (i.e. set them to 1). Made sure to switch coil driver state to 1 (high range). Ran damping loops for a minute between each DOF. ITMY M0 was measured with 0.02 Hz BW. Want to do 0.01 Hz BW to resolve resonances, but didn't notice until too late (in order to process with matlab scripts, all DOFs need to be the same BW and Freq Range). Don't think it negates results, but a bummer. ITMX R0 R P and Y have less than 5 averages, but it was obvious from first few averages that nothing was wrong.