Displaying report 1-1 of 1.
Reports until 08:07, Sunday 23 July 2017
H1 General
cheryl.vorvick@LIGO.ORG - posted 08:07, Sunday 23 July 2017 - last comment - 10:56, Sunday 23 July 2017(37711)
Ops Owl Summary:

TITLE: 07/23 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: TJ
SHIFT SUMMARY: started with locked, lost lock, relocked, lost lock due to monster PI modes 27 and 28, relocked,
LOG:

Comments related to this report
cheryl.vorvick@LIGO.ORG - 08:12, Sunday 23 July 2017 (37712)

I've tested the addition of +30deg phase on ITMY ROLL and for this lock I saved F6 in SDF, but ran out of time to modify guardian.

cheryl.vorvick@LIGO.ORG - 09:26, Sunday 23 July 2017 (37715)
  • not sure if this is significant, but I've been noticing peaks in SRCL, and they come and go
  • they were there in the first lock of my shift, but are not there now, the last lock of my shift
  • snapshots attached, lock with peaks first, then current lock
Images attached to this comment
thomas.shaffer@LIGO.ORG - 10:56, Sunday 23 July 2017 (37717)

The new filter worked well for me as well. I added it to ISC_LOCK