ling.sun@LIGO.ORG - posted 23:56, Wednesday 26 July 2017 (37809)
Large violin resonances on July 24 and 25
This is to report that the violin resonances were much larger on July 24 and 25, which produced cross-coupling effects and impacted a large band for CW and stochastic analysis. The situation seems to be much better on July 26 although only 5-hr data were collected on July 26. Also there were a lot new lines from ~ 20Hz to 70Hz, which got better on July 26 too.

There seem to be quite a few entries about the rung-up violin modes and this probably is an known issue, but we are flagging this from the perspective of CW/stochastic analysis. 

Attached are the full 4k and 0-100Hz spectra on July 24, 25, 26, respectively. 