Displaying report 1-1 of 1.
Reports until 16:16, Thursday 27 July 2017
H1 SEI (OpsInfo)
jim.warner@LIGO.ORG - posted 16:16, Thursday 27 July 2017 (37825)
Seismon update

I think I have the seismon code running a bit better now. At least it is running on it's own, and hasn't needed restarting since last week. The main differences are now the 5 event epics code looks like its running, and the seismon_run_info script I'm using now touches on the current event folder every loop. I think this was getting "cleaned up" before and not getting recreated or something. I've added a test to diag main if any earthquake has an arrival time in the future, so there is at least some notification that an earthquake is coming. This should be in addition to the verbal test (which may need updated? I'm not sure what TJ has done) that also has a threshold on the predicted ground velocities. The earthquake today was below the verbal threshold, so didn't get noticed by verbal alarms, but seismon gave us plenty of warning.

Displaying report 1-1 of 1.