Reports until 16:27, Thursday 27 July 2017
H1 DetChar
john.zweizig@LIGO.ORG - posted 16:27, Thursday 27 July 2017 - last comment - 16:40, Thursday 27 July 2017(37826)
DMT Segment generation restarted to include H1:DMT-ITMY_L2_DAC_OVERFLOW segments
I have restarted SegGener_H1 to include the H1:DMT-ITMY_L2_DAC_OVERFLOW as defined by TJ. This shouldn't have any side effects other than a loss of 1-2 secons of segment data. The H1 IFO was not in low noise data taking at the time so this shouldn't matter much.
Comments related to this report
gregory.mendell@LIGO.ORG - 16:40, Thursday 27 July 2017 (37827)

John reported via email this change was successful on the production machine, but the DMT test machine hung (probably for other reasons) when he was testing the change. I've now power cycled h1dmt3, and it is up again. This completes LHO WP 7094.