NLN SDF difference
Found the attached SDF difference at NLN. Reverting.
Images attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG
- 17:56, Saturday 29 July 2017 (37876)
Link
Maybe from skipping VIOLIN_MODE_DAMPING_1?