sheila.dwyer@LIGO.ORG - posted 17:15, Monday 31 July 2017 - last comment - 10:00, Tuesday 01 August 2017(37918)
violin mode damping off
We have left the violin mode damping off for one lock, with the intention of measuring violin mode Qs to compare to what was measured in 23383. We had the damping off starting at 00:05:00 UTC, and will leave it off for the rest of this lock.
Comments related to this report
sheila.dwyer@LIGO.ORG - 10:00, Tuesday 01 August 2017 (37935)
ETMY MODE 7 rang up, and possibly ETMY MODE 2. If this data is unusable, we can try this again but leave all the damping on for ETMY.