Reports until 09:48, Tuesday 08 August 2017
H1 PSL
thomas.shaffer@LIGO.ORG - posted 09:48, Tuesday 08 August 2017 (38073)
PSL Weekly Report

FAMIS7450

Laser Status:
SysStat is good
Front End Power is 33.9W (should be around 30 W)
HPO Output Power is 154.8W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 20 days, 23 hr 9 minutes (should be days/weeks)
Reflected power = 17.42Watts
Transmitted power = 57.23Watts
PowerSum = 74.65Watts.

FSS:
It has been locked for 0 days 2 hr and 35 min (should be days/weeks)
TPD[V] = 1.875V (min 0.9V)

ISS:
The diffracted power is around 2.9% (should be 3-5%)
Last saturation event was 0 days 0 hours and 55 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high