ext_alert (GRB and SN notifications) certificate expired, new cert installed, h1fescript0 rebooted

Jonathan, Carlos, Dave:

the GraceDB database access certificate on h1fescript0 expired today, meaning that GRB and SN alerts could not be raised in the control room. Jonathan and Carlos obtained a new cert and installed it in record time. I noticed this machine had been running for 383 days, and needed a reboot to install patches, so I took this opportunity to reboot it.

There was some confusion on starting the seismon IOC code (currently we need both the old and new code), and I missed the restart of the camera copy program.

I'm updating the relevant CDS wiki pages related to code running on this machine.