Following up on some remote MEDM display problems Sheila was experiencing which could have been due to some screens with (x,y) origin coordinates at high values, I wrote a python script to find which ADL files with bad origins.
Rather than scan every ADL file under the userapps area (there are 9,449 of them) my code starts at the SITEMAP.adl and drills down through all the related displays. It is not totally inclusive as some related display paths heavily use macro substitution.
Of the 4085 files scanned, 111 of them have an origin outside of the single monitor iMac resolution range of (2560,1440). Since these files are under svn control, I'll see how we can go about fixing this.