Displaying report 1-1 of 1.
Reports until 09:32, Friday 11 August 2017
H1 General
paul.marsh@LIGO.ORG - posted 09:32, Friday 11 August 2017 (38140)
ETMY NoiseMon and HVeto
Based on some follow up from an HVeto journal club, I sanity-checked my claim that ETMY L1 NoiseMon channels are winning HVeto nearly every day. Attached are said results.

In viewing the data from Jun-8 until Aug-9, one of the four ETMY L1 channels begins showing up as the consistent round 1 winner on June 27; it occasionally pushes back to round 3 due to other exceptionally noisy aux channels. This trend continues through until today. Also, the LL channel is the most consistent winner (about 60% of all round wins).

In the attached plots, the regions where it is not a round winner (7-Jul to 13-Jul) simply have no HVeto output. I assume these channels would have continued to lead otherwise.

Further time series analysis of glitches to come.
Images attached to this report
Displaying report 1-1 of 1.