Data for ETMX and ETMY for 3 EQs:
I've included drive signals, sensors (osems), and then subtracted the drive signals from the sensor (osem) signals (on speculation, no claim this is completely valid, outside of M0), with some interesting results.
There are a number of sensors that have large changes compared to the other osems around them, and some that are large in both sensors and sensors-drives.
This leads me to believe that further investigation into these osems may be warented.
All values the change from before to after the earthquakes, and all comments are regarding EQ2 only.
| osems | osems - drive | ||
| ETMX | M0 | RT: large change | RT: large change |
| L1 | LL, UR: large change | all osems: no remarkable changes | |
| L2 | UL, UR: large changes | all osems: inconsistent changes | |
| ETMY | M0 | RT: large change | RT: large change |
| M0 | SD: nothing remarkable | SD: large change | |
| L1 | LL: large change | LL: large change | |
| L2 | UL: large change | all osems: no remarkable changes | |
| L2 | LL and UR: small change | all osems: no remarkable changes |