david.barker@LIGO.ORG - posted 17:42, Friday 10 August 2012 (3815)
IOP Sus Watchdog installed on HAM 2 and 3

I have installed the IOP SUS watchdog system for the H1 HAM2,3 systems. The sus systems are h1sush2a and h1sush34, the seismic system is h1seih23. Following the LLO system, the suspension systems being monitored are

HAM2: PR3

HAM3: PR2 and MC2

If any of these sus system trip, the DACs on h1seih23 (HEPI and ISI in HAMS 2,3) are tripped via the Dolphin IPC.

Currently SEI HAM2,3 is permanently tripped due to missing PR3 OSEMS. I will reconfigure the system into a working state when the ISI are unlocked in HAM2/3.

The H1 IOP watchdog MEDM is available from the H1 SITEMAP