2017-08-16 Calibration Measurements Complete
J. Kissel

Was able to grab an entire suite of calibration measurements this afternoon. Data files listed below, will process in due time. Preliminary results are as expected -- attached is a screen shot of "perfect" reference calibration against current CAL-DELTAL_EXTERNAL, which we know is *not* corrected for time dependent correction factors -- namely kappa_TST which is up at ~10% at the moment, likely causing the shown discrepancy.

Actuation:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Measurements/FullIFOActuatorTFs/2017-08-16
2017-08-16_H1SUSETMY_L1_iEXC2DARM_25min.xml
2017-08-16_H1SUSETMY_L1_PCAL2DARM_8min.xml
2017-08-16_H1SUSETMY_L2_iEXC2DARM_17min.xml
2017-08-16_H1SUSETMY_L2_PCAL2DARM_8min.xml
2017-08-16_H1SUSETMY_L3_iEXC2DARM_8min.xml
2017-08-16_H1SUSETMY_L3_PCAL2DARM_8min.xml

Sensing:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O2/H1/Measurements/SensingFunctionTFs
2017-08-16_H1DARM_OLGTF_4to1200Hz_25min.xml
2017-08-16_H1_OMCDCPDSUM_to_DARMIN1.xml
2017-08-16_H1_PCAL2DARMTF_4to1200Hz_8min.xml
2017-08-16_H1_PCAL2DARMTF_BB_5to1000Hz_0p25BW_250avgs_5min.xml
Images attached to this report