Displaying report 1-1 of 1.
Reports until 11:43, Wednesday 16 August 2017
H1 SEI (OpsInfo)
jim.warner@LIGO.ORG - posted 11:43, Wednesday 16 August 2017 - last comment - 17:04, Wednesday 16 August 2017(38229)
Seismon Code found dead this morning

Over the weekend, I the seismon code had died. I don't know why it died over the weekend, but it looks like I may have restarted some wrong versions of epics code. Corey had found it dead again after my last shift, probably a result of the epics code crashing in a way that's not totally obvious on the medm display. I restarted the right versions of the code this morning, but it's hard tell if it's actually, really running, so it needs monitoring. If the code is found not running again, I'd like to know, so I can try to diagnose the code. Some symptoms are the gps clock on the medm is dead (this will turn on a red  light on my new medm & there is a diag_main test) or not catching new earthquakes. Also, the new version of the code seems to have more or less killed the old display, so there is no need to report on the old, single event seismon not updating.

Comments related to this report
jeffrey.bartlett@LIGO.ORG - 17:04, Wednesday 16 August 2017 (38239)
   Seismon looks dead again. The Dead box on the wall display is red. DIAG_MAIN is showing the "Seismon system not updating" message. Seismon-5 has not updated since 15:53:27utc, Terramon shows several EQs arriving after 15:53.   