cheryl.vorvick@LIGO.ORG - posted 09:31, Thursday 17 August 2017 - last comment - 12:39, Thursday 17 August 2017(38246)
TCSX laser is off - PeterK heading out to reset - cause was a drop in chiller flow
Comments related to this report
cheryl.vorvick@LIGO.ORG - 10:58, Thursday 17 August 2017 (38249)

TCSX is back - H1 in Observe - details to follow

cheryl.vorvick@LIGO.ORG - 11:19, Thursday 17 August 2017 (38250)DetChar

Initial exit of H1 from Observe:

  • 1187018572 - chiller flow (blue) drops low enough to shut the laser off (red)
  • shortly after the SDF for TCSX goes from 0 to 1, and then 1 to 2, which kicks H1 out of Observe
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 12:39, Thursday 17 August 2017 (38252)

H1 recovery / return to Observe:

  • 16:48:35 UTC - Thermal effects and TCSX guardian recovery are both complete - plot attached
  • 16:49:00UTC - H1 in Observe
Images attached to this comment