corey.gray@LIGO.ORG - posted 08:12, Sunday 20 August 2017 - last comment - 09:02, Sunday 20 August 2017(38281)
Transition To DAY

TITLE: 08/20 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Jim
CURRENT ENVIRONMENT:
    Wind: 7mph Gusts, 4mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.09 μm/s
QUICK SUMMARY:

As Jim and I were chatting before he left, H1 broke lock!  (No obvious seismic reasons or anything else seen for a cause).  Currently taking back up.

Comments related to this report
corey.gray@LIGO.ORG - 09:02, Sunday 20 August 2017 (38282)

Notes On Relocking So Far:

It's been a couple of weeks since I've locked. 

The PRMI cavity looked dead at first, so I went to CHECK MICH FRINGES, & it still looked like it was in the doldrums, but managed to see that it needed some BS YAW---miraculously PRMI then locked on the quick. 

As TJ noted, AS90 is different (for the PRMI locking steps, it is up around 2000 counts [just barely visible on StripTool], so I ignored that channel).  The PRMI/DRMI transition looked odd/slow motion during the transition, but made the switch without breaking lock.

Other than that, had no issue with getting back to OBSERVING.