Reports until 14:04, Sunday 20 August 2017
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 14:04, Sunday 20 August 2017 (38285)
PSL Weekly Report (FAMIS #7452)

Notables:  ISS saturation about 6hrs ago & PMC Refl is high.

Laser Status:
SysStat is good
Front End Power is 33.89W (should be around 30 W)
HPO Output Power is 154.7W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 5 days, 4 hr 12 minutes (should be days/weeks)
Reflected power = 17.05Watts
Transmitted power = 56.95Watts
PowerSum = 74.0Watts.

FSS:
It has been locked for 0 days 5 hr and 56 min (should be days/weeks)
TPD[V] = 1.43V (min 0.9V)

ISS:
The diffracted power is around 3.3% (should be 3-5%)
Last saturation event was 0 days 5 hours and 54 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high