Charge Measurement Update; Maybe There Wasn't a Jump Increase in Charge after Jul 2017 EQ?
J. Kissel

Took regular charge measurements yesterday. Results for ETMY are beginning to wash out what effects we thought we might have seen after the July 6th 2017 EQ -- I'd argue that it's now a toss up in terms of each quadrant whether the effective bias voltage showed a significant step, or just apparently so given the gap in the data for ~6 weeks. ETMY's worst quadrants (ETMY UL in Pitch) are now at -93 [V], which is about 25% of the applied effective bias voltage (380 [V]). However, though angular the effective bias voltage has changed from -11 [V] to -92 [V] (a change of (93-11)/380 = 21%), the relative actuation strength in longitudinal -- as measured by calibration lines, reported on the summary pages -- has only changed by 10%. 

ETMX remains at a reasonably low level of effective bias voltage, where the worst quadrants (ETMX LL and LR) are showing effective bias voltages of ~40 [V], but the mean (average of all eight measurements, 4 quadrants in P and Y) is 20 [V]. This is mildly inconsistent with what Sheila has measured recently -- -5.2 [V] -- via longitudinal drive (see LHO aLOG 38233) However, I look forward to seeing the results of the test mass discharge system, slated to be used next Tuesday (2017-08-29).

All effective bias voltages reported by the angular actuation strength have an uncertainty at the level of 1-2 [V]