Displaying report 1-1 of 1.
Reports until 09:14, Friday 25 August 2017
H1 SEI
hugh.radkins@LIGO.ORG - posted 09:14, Friday 25 August 2017 - last comment - 11:47, Friday 25 August 2017(38367)
STS2 Wind/Floor Tilting Measurement now at Roam9

Thursday afternoon we had a brief but strong wind event--See first plot: 2 day's minute trends.  I had moved the roaming STS2 a week or more ago and now resides at position Roam9.  At the corner station the wind average touched on 20mph for maybe 90 minutes with a stable direction of about 170o or ~from EndX toward the corner.  No non-wind seismic evident.

The second attachment shows the usual STS ASD comparisons between the Roaming HAM5 and the Detector used ITMY STSs, see 38184 for the Roam8 comparison and you can follow back from there.  Great news: for the X dof here at Roam9, the HAM5 STS shows several factors less floor tilting than ITMY starting at 30ishmHz; and, the Y dof is maybe no worse--is that band between 10 & 100mHz too much?

So bottom line Roam9 shows promise!

Times: RefTime is low wind, 25 Aug 0930 utc.  High wind is 0130 25 Aug.  XMLs in /ligo/home/hugh.radkins/STS_Seismometer_Studies

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 11:47, Friday 25 August 2017 (38369)

Latest locations.

Non-image files attached to this comment
Displaying report 1-1 of 1.