patrick.thomas@zotws7:~$ check_sdf_snapfiles_status WARNING: local modification on file /opt/rtcds/userapps/trunk/psl/h1/burtfiles/fss/h1pslfss_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/psl/h1/burtfiles/fss/h1pslfss_safe.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/omc/h1/burtfiles/h1omc_OBSERVE.snap WARNING: local modification on file /opt/rtcds/userapps/trunk/tcs/h1/burtfiles/h1tcscs_OBSERVE.snap h1pslfss_safe.snap: -Time: Tue Aug 15 16:38:08 2017 +Time: Fri Aug 25 00:27:45 2017 -H1:PSL-FSS_COMMON_GAIN 1 1.600000000000000e+01 1 +H1:PSL-FSS_COMMON_GAIN 1 1.602103999999996e+01 1 h1omc_OBSERVE: -Time: Tue Jul 18 12:07:52 2017 +Time: Fri Aug 25 00:27:37 2017 -H1:LSC-ASAIR_A_RF45_I_OFFSET 1 -7.589000000000000e+01 1 +H1:LSC-ASAIR_A_RF45_I_OFFSET 1 -7.220000000000000e+01 1 -H1:LSC-ASAIR_A_RF45_Q_OFFSET 1 2.000000000000000e+01 1 +H1:LSC-ASAIR_A_RF45_Q_OFFSET 1 2.150000000000000e+01 1 h1tcscs_OBSERVE.snap: -Time: Tue Apr 4 18:11:09 2017 +Time: Thu Aug 24 03:19:07 2017 Changes committed.