in lock charge measurements

On friday Thomas and I ran excitations on all 4 ESDs in order to measure the 4 coefficients in this equation for the force applied by the ESDs (G1600699) Equation 2:

F = α (V_b-V_s)2 +β (V_b+V_s)+ β _2(V_b-V_s)+γ (V_b+V_s)2

The first 2 excitations for each suspension were on the bias path with no signal voltage so that the linear response is:

F = [β+β_2+2(α+γ)V_b] δV_b

The bias path was excited twice, first with the normal bias of 380 V on and second with no bias. Then the script excited the signal path which gives a linear response of:

F = [β-β_2+2(α+γ)V_b+2(α-γ)V_s] δV_s

This path is excited 3 times, once with no DC offset on any electrodes, once with an offset of 7.6Volts on the signal electrodes, and once with the bias at its normal value of 380V.

The first 4 of these measurements allow us to make a complete measurement of all four coefficents, α, β β_2, and γ The fifth measurement is redundant and could be skipped, I used it as a sanity check.  I am still worried that I have some signs wrong which are making these results confusing.  

  ETMX ETMY ITMX ITMY
α (N/V^2) 2.1e-10 2.0e-10 8e-11 5.5e-11
β(N/V) -9.9e-10 2.0e-8 1.0e-8 5.6e-9
β_2 (N/V) 2.8e-9 3.2e-8 -4.2e-9 -8.5e-9
γ 1.5e-10 1.2e-10 -4.0e-11 -1.2e-11
V_eff = (beta-Beta2)/(2*(alpha-gamma)) -31 V -75 V 60 V 105 V

All of the scripts needed for taking the measurement and getting the coefficents are in userppas/sus/common/quad/scripts/InLockChargeMeasurements/

Non-image files attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 20:01, Monday 28 August 2017 (38409)

The table above is wrong because of multiple minus signs (which are different between the ITM and ETM ESD drivers) being wrong.  Here is a corrected table:

  ETMX ETMY ITMX ITMY
α (N/V^2) 9.6e-11 8.7e-11 4.9e-11 5.8e-11
β(N/V) -1e-9 2e-8 -1e-8 -5.6e-9
β_2 (N/V) 2.8e-9 3.2e-8 4.2e-9 8.5e-9
γ 2.6e-10 2.3e-10 -9.2e-12 -1.5e-11
V_eff = (beta-Beta2)/(2*(alpha-gamma)) 12 38 -124 -97

 

sheila.dwyer@LIGO.ORG - 09:51, Wednesday 20 September 2017 (38718)

The values in this table still had some calibration errors.  New log coming soon.