Reports until 11:14, Tuesday 29 August 2017
H1 PSL
thomas.shaffer@LIGO.ORG - posted 11:14, Tuesday 29 August 2017 - last comment - 11:15, Tuesday 29 August 2017(38417)
PSL Weekly Report


Laser Status:
SysStat is good
Front End Power is 33.8W (should be around 30 W)
HPO Output Power is 154.8W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 14 days, 1 hr 23 minutes (should be days/weeks)
Reflected power = 16.87Watts
Transmitted power = 57.1Watts
PowerSum = 73.97Watts.

FSS:
It has been locked for 0 days 1 hr and 12 min (should be days/weeks)
TPD[V] = 1.446V (min 0.9V)

ISS:
The diffracted power is around 3.2% (should be 3-5%)
Last saturation event was 0 days 1 hours and 12 minutes ago (should be days/weeks)

Possible Issues:

None

Comments related to this report
thomas.shaffer@LIGO.ORG - 11:15, Tuesday 29 August 2017 (38418)

This closes FAMIS7453