The latest H1 SUS PR2 transfer function measurements were taken on the M1 stage this afternoon. Data has been exported to .txt files and the DTT .xml templates saved. Plots of the data with the model trace are attached. Plots with previous measurements to follow. DTT .xml files and exported .txt files are saved and committed to the SUS SVN locally under: '/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Data/' DTT .xml file names used: 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.xml 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.xml 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.xml 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.xml 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.xml 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.xml Exported .txt file names used: 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.txt 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.txt 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.txt 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.txt 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.txt 2012-08-14_1720_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.txt PDFs of plots: '/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Results/' Saved as: 2012-08-14_1720_H1SUSPR2_M1_*_TF*.pdf