Reports until 16:13, Tuesday 05 September 2017
H1 PSL (PSL)
cheryl.vorvick@LIGO.ORG - posted 16:13, Tuesday 05 September 2017 (38529)
PSL Weekly

Laser Status:
SysStat is good
Front End Power is 33.77W (should be around 30 W)
HPO Output Power is 154.9W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 4 days, 6 hr 44 minutes (should be days/weeks)
Reflected power = 17.36Watts
Transmitted power = 57.32Watts
PowerSum = 74.68Watts.

FSS:
It has been locked for 0 days 0 hr and 7 min (should be days/weeks)
TPD[V] = 0.9954V (min 0.9V)

ISS:
The diffracted power is around 2.9% (should be 3-5%)
Last saturation event was 0 days 6 hours and 21 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high