The DAMP ON PR2 transfer function measurements were taken yesterday afternoon and this morning. Data has been exported to .txt files and the DTT .xml templates saved. DTT .xml files and exported .txt files are saved and committed to the SUS SVN locally under: '/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Data/' DTT .xml file names used: 2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.xml 2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.xml 2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.xml 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.xml 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.xml 2012-08-14_1810_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.xml Exported .txt file names used: 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_L_0p1to50Hz.txt 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_T_0p1to50Hz.txt 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_V_0p1to50Hz.txt 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_R_0p1to50Hz.txt 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_P_0p1to50Hz.txt 2012-08-15_1438_H1SUSPR2_M1_WhiteNoise_Y_0p1to50Hz.txt PDFs of plots: '/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PR2/SAGM1/Results/' Saved as: 2012-08-15_1438_H1SUSPR2_M1_*_TF*.pdf Data committed.