Earlier it was suspected that the flow rate trip point for the TCSX laser was different from the TCSY laser
because of component value differences for the comparator setpoint voltage. Both controllers have R115 = 4.87k,
R12 = 10.0k and R11 not stuffed.
So the trip setpoints are the same and is not the reason for the difference.