Reports until 00:16, Tuesday 12 September 2017
H1 ISC
sheila.dwyer@LIGO.ORG - posted 00:16, Tuesday 12 September 2017 - last comment - 14:49, Wednesday 20 September 2017(38608)
a couple more ESD measurements

I did a couple more measurements of the ESD actuation tonight.

1)I re-ran the script that allows us to measure 4 coefficicents for each test mass, (described in 38387).  Plots coming soon...

2) I measured Veff by driving the signal electrodes in length while we were locked and adjusting the bias voltage to minimize the coupling to DARM.  This can be checked against the results from the first measurement.  Veff = (beta-beta2)/2(gamma-alpha)

3) For some optics I also measured a different effective bias, by driving the bias path at 12 Hz and changing the offset in the bias path to minimize the coupling to DARM.  Veff 2= (beta+beta2)/2(alpha+gamma)

  Veff Veff 2 (driving bias)
ETMX -10.8  
ETMY 24.13 38
ITMX 122.4 -53.6
ITMY 95 54.8

Here I have written these as positive if the voltage requested out of the DAC is positive, although in reality there is a sign flip in some of the drivers (I will edit this entry in the morning with the correct sign).

Comments related to this report
sheila.dwyer@LIGO.ORG - 14:49, Wednesday 20 September 2017 (38723)

The signs are wrong for the ITMs in this table.  Multiply all ITM results by -1.