In order to complete the individual data set for H1 SUS PR2's phase 2B testing, I attach the amplitude spectral densities of all stages of OSEMs. Tough to determine anything from these plots:
- there's so many dang plots,
- one is only comparing damping ON vs OFF, so you're only looking for "do the damping loops
- Damp the resonances
- Add any unexpected additional noise at any stage"
but given those limited criteria, the answer is "looks fine..."