WHAM3 H2 CPS Noisy again but only after recovery from Power Glitch

The attached plot shows 10 days of the HAM2 Corner2 Horizontal CPS.  There is about 24 hours of low noise condition after I power cycled the CPS section of the Interface Chassis.  The Saturday power glitch is obvious as is the noise level after front end recovery.  I'll do the power cycle again but it is weird to power cycle to correct a problem originating from by a power cycle.

Images attached to this report
Comments related to this report
hugh.radkins@LIGO.ORG - 16:40, Tuesday 19 September 2017 (38714)

Still appears quiet after...5 hours maybe it is has been since I power cycled the Interface Chassis.