Displaying report 1-1 of 1.
Reports until 11:39, Wednesday 20 September 2017
H1 CDS (PEM)
david.barker@LIGO.ORG - posted 11:39, Wednesday 20 September 2017 (38720)
updated dust monitor check script for new dust monitors in LVEA

Jeff B, Dave:

I have updated the check_dust_monitors_are_working script to scan all the LVEA dustmonitors, and added both 300nm and 500nm channels. I also modified the script to allow the user to specify the look-back time in hours (used to be days). This is needed as the script cannot transit a daq restart time.

Here is the output for the past 20 hours of dust data:

david.barker@zotws6: check_dust_monitors_are_working 20
H1:PEM-CS_DUST_LVEA2_300NM_PCF           Channel Statistics: mean    9.43 max  280.00 std-dev   33.31 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA2_500NM_PCF           Channel Statistics: mean    1.94 max   40.00 std-dev    6.41 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA3_300NM_PCF           Channel Statistics: mean  114.62 max 10320.00 std-dev 1026.39 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA3_500NM_PCF           Channel Statistics: mean  101.03 max 7970.00 std-dev  803.59 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA4_300NM_PCF           Channel Statistics: mean    4.57 max   30.00 std-dev    6.38 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA4_500NM_PCF           Channel Statistics: mean    0.00 max    0.00 std-dev    0.00 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA5_300NM_PCF           Channel Statistics: mean    6.78 max  320.00 std-dev   31.90 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA5_500NM_PCF           Channel Statistics: mean    7.40 max  740.00 std-dev   73.63 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA6_300NM_PCF           Channel Statistics: mean    6.12 max  200.00 std-dev   20.86 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA6_500NM_PCF           Channel Statistics: mean    3.16 max  250.00 std-dev   25.34 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA10_300NM_PCF          Channel Statistics: mean   30.58 max 2590.00 std-dev  257.52 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA10_500NM_PCF          Channel Statistics: mean   24.54 max 2130.00 std-dev  213.26 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA30_300NM_PCF          Channel Statistics: mean    4.78 max   30.00 std-dev    6.08 (20 hour(s) minute trends)
H1:PEM-CS_DUST_LVEA30_500NM_PCF          Channel Statistics: mean    1.45 max   70.00 std-dev    8.00 (20 hour(s) minute trends)
H1:PEM-CS_DUST_PSL101_300NM_PCF          Channel Statistics: mean    0.68 max   15.00 std-dev    1.72 (20 hour(s) minute trends)
H1:PEM-CS_DUST_PSL101_500NM_PCF          Channel Statistics: mean    0.31 max   24.00 std-dev    2.42 (20 hour(s) minute trends)
H1:PEM-CS_DUST_PSL102_300NM_PCF          Channel Statistics: mean    4.32 max   50.00 std-dev    8.14 (20 hour(s) minute trends)
H1:PEM-CS_DUST_PSL102_500NM_PCF          Channel Statistics: mean    0.10 max   10.00 std-dev    0.99 (20 hour(s) minute trends)
H1:PEM-EX_DUST_VEA1_300NM_PCF            Channel Statistics: mean   13.76 max  150.00 std-dev   22.49 (20 hour(s) minute trends)
H1:PEM-EX_DUST_VEA1_500NM_PCF            Channel Statistics: mean    5.99 max   60.00 std-dev   10.98 (20 hour(s) minute trends)
H1:PEM-EY_DUST_VEA1_300NM_PCF            Channel Statistics: mean  675.02 max 4180.00 std-dev 1015.13 (20 hour(s) minute trends)
H1:PEM-EY_DUST_VEA1_500NM_PCF            Channel Statistics: mean   22.69 max  160.00 std-dev   34.25 (20 hour(s) minute trends)
david.barker@zotws6:

 

Displaying report 1-1 of 1.