Reports until 16:42, Monday 25 September 2017
H1 TCS (TCS)
aidan.brooks@LIGO.ORG - posted 16:42, Monday 25 September 2017 (38774)
TCS userapps SVN updated

I've updated the local copy of the TCS folder in USERAPPS.

The HWS data disk was full. After checking that the data was backed up on LDAS, I removed the contents of the /data/H1/ETMY_HWS/1188900000/ directory/

Updated the stream_image aliases on H1HWSEY, H1HWSEX, H1HWSMSR, H1HWSMSR1.

alias stream_image_EY='python /opt/rtcds/userapps/release/tcs/common/hws_code/utilities/stream_HWS_intensity.py 0'

alias stream_image_EX='python /opt/rtcds/userapps/release/tcs/common/hws_code/utilities/stream_HWS_intensity.py 0'

alias stream_image_ITMX='python /opt/rtcds/userapps/release/tcs/common/hws_code/utilities/stream_HWS_intensity.py 1'

alias stream_image_ITMY='python /opt/rtcds/userapps/release/tcs/common/hws_code/utilities/stream_HWS_intensity.py 0'

The stream_image code works for ETMX and ETMY but not for the ITMs. HWS cameras are not connected at the ITMs so we'll have to wait to check those.