Reports until 16:26, Friday 29 September 2017
H1 SUS
jeffrey.kissel@LIGO.ORG - posted 16:26, Friday 29 September 2017 - last comment - 16:27, Friday 29 September 2017(38843)
H1 SUS SRM -- Now Monolithic -- Preiliminary Transfer Functions Look Great
J. Kissel

After SRM's surrogate optic was replaced by the real thing yesterday (see LHO aLOG 38833), it was rebalanced and leveled this morning. With it's lower stage OSEMs still completely backed off, I ran a set of health-check transfer functions to confirm that the new mass is suspended well and that the dynamics are currently free and haven't changed much from the surrogate. I'm happy to report, the transfer functions look wonderful. I attach plots of its Top to Top (M1 to M1) transfer functions by itself (with more DOFs shown in detail) and a before vs. comparison between the composite and monolithic masses for both L1 and H1.

Nice work install team!!

All data and changes to transfer function plotting scripts have been committed to the SusSVN:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Data/
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_L_0p01to50Hz.xml
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_P_0p01to50Hz.xml
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_R_0p01to50Hz.xml
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_T_0p01to50Hz.xml
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_V_0p01to50Hz.xml
    2017-09-29_2216_H1SUSSRM_M1_WhiteNoise_Y_0p01to50Hz.xml

/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/MatlabTools/
    plotHSTS_dtttfs_M1.m

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/SAGM1/Results/
    2017-09-29_2216_H1SUSSRM_M1_ALL_TFs.pdf
    2017-09-29_2216_H1SUSSRM_M1.mat

/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/MatlabTools/
    plotallhsts_tfs_M1.m

/ligo/svncommon/SusSVN/sus/trunk/HSTS/Common/Data/
    allhstss_2017-09-29_Phase3a_H1SUSSRM_NoDamping_ALL_TFs.pdf
    allhstss_2017-09-29_Phase3a_H1SUSSRM_NoDamping_ALL_ZOOMED_TFs.pdf
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 16:27, Friday 29 September 2017 (38845)OpsInfo
FYI: I've left SRM in the DAMPED configuration for over the weekend.