Displaying report 1-1 of 1.
Reports until 14:22, Tuesday 03 October 2017
H1 SUS
betsy.weaver@LIGO.ORG - posted 14:22, Tuesday 03 October 2017 - last comment - 14:51, Tuesday 03 October 2017(38875)
SRM M2 and M3 AOSEM dark offsets measured

WHile the lower stage AOSEMs were pulled back over the last few days on SRM, I did a quick look at the dark offsets.  Of course, the "pretty" OSEM offset script wouldn't work due to many years of CDS software tool upgrades since it's last uese (thanks Jim for tyring), so I just ran them by hand, and plugged them into the associated MEDM screens:

   M2

  NEW OLV OFFSET WAS OFFSET NOW GAIN WAS GAIN NOW
UL 24350 -13573 -12175 1.105 1.232
LL 23240 -13887 -11620 1.08 1.291
UR 24350 -13423 -12175 1.118 1.232
LR 21780 -12388 -10890 1.211 1.377
     M3          
UL 22240 -13741 -11120 1.092 1.349
LL 23100 -12966 -11550 1.157 1.3
UR 23160 -13527 -11580 1.109 1.295
LR 20850 -12420 -10425 1.208 1.439

The OSEM strengths look to be decaying a bit.

Also, I set the pitch and yaw alignment sliders both to 0 since it is getting a fresh start.  (Bias sliders were P=-666.3, Y = 927.4)

Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:51, Tuesday 03 October 2017 (38877)
For the record, I've accepted these new open light current values for SRM into the safe.snap of the SDF system this morning, such that they survived the h1sussrm front-end process reboot to remove the HAM5 optical lever (see LHO aLOG 38868). See attached screenshot.
Images attached to this comment
Displaying report 1-1 of 1.