WP7162 Sheila, Patrick, Jeff, Dave:

h1susauxh56: latest version of this code was installed.

h1susopo: DACKILL part in OFI was removed.

h1isiham2: new IPC sender channels (qty 4) added.

h1isiham5: new IPC channels (qty 2), DAQ changes, 12 fast channels added to frame.

h1isiham6: new IPC channels (qty 5), DAQ changes, 12 fast channels added to frame.

h1oaf: IPC receivers added.

Sheila and Patrick updated the SQZ beckhoff PLC DAQ ini file. I added it to the DAQ for the first time.

DAQ was restarted to resync with: h1susauxh56, h1susopo, h1isiham[5,6], h1oaf, H1EDCU_ECATC1PLC4

Restarts were unremarkable, partial second trend file was renamed as per normal procedure.

 

Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:12, Monday 09 October 2017 (38944)DetChar, ISC, SQZ, SUS
J. Kissel, D. Barker

Description of changes to ISI and OAF top-level models can be found in LHO aLOG 38943.