H1 SQZ (CDS, DAQ)
david.barker@LIGO.ORG - posted 15:41, Thursday 12 October 2017 - last comment - 15:44, Thursday 12 October 2017(39013)
Added h1sqz model to h1lsc0 on 7th core

I have created a placeholder h1sqz model and started it on h1lsc0. It has dcu-id=76, a processing rate of 16384Hz and runs on the 7th core of this new 10 core machine.

I have not yet added h1sqz to the DAQ. I'll do that when we next restart the DAQ.

I have added the model to the CDS Overview MEDM (see attached).

I believe this completes the new parts needed in CDS computing for Squeezer install.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 15:44, Thursday 12 October 2017 (39014)

BTW: after reporting how to annotate PNGs using GIMP, Vern countered with a suggestion of using INKSCAPE instead. So in the spirit of impartiality here are the inkscape instructions