This is a good time to summarize the CDS Computing changes completed for Squeezer install
h1asc0:
Removed 8th ADC.
Removed 2nd 16bit-DAC
Removed h1sushtts model
Removed h1susauxasc0 model
Modified h1asc and h1ascimc models to use 1st 16bit-DAC instead of 2nd card
Modified h1iopasc0 model to reflect new IO Chassis hardware configuration
Added h1sqzwfs model (dcuid=77)
h1lsc0:
Upgraded computer to fast 10 core machine
Added ADC card
modified h1ioplsc0 to reflect new IO Chassis hardware configuration
Added h1sqz model (dcuid=76)
h1sush56:
Added two 16bit-DAC cards
Modified h1susomc model to add OM1,2,3 (originally in h1sushtts)
Added new h1susopo model (dcuid=22) for VOPO, OFI, ZM1,2
Modified h1iopsush45 to reflect new IO Chassis hardware configuration
h1sush2b:
Added 16bit-DAC card
Added h1sushtts model (dcuid=21) for RM1,2
Modified h1iopsush2b to reflect new IO Chassis hardware configuration
h1susauxh56:
Added ADC card
Modified h1susauxh56 model, added SQZ aux channels
Modified h1iopsusauxh56 to reflect new IO Chassis hardware configuration
h1susauxh2:
Modified h1susauxh2 model to add RM1,2 aux channels