Summary of new parts in CDS Computing for Squeezer Install

This is a good time to summarize the CDS Computing changes completed for Squeezer install

h1asc0:

Removed 8th ADC.

Removed 2nd 16bit-DAC

Removed h1sushtts model

Removed h1susauxasc0 model

Modified h1asc and h1ascimc models to use 1st 16bit-DAC instead of 2nd card

Modified h1iopasc0 model to reflect new IO Chassis hardware configuration

Added h1sqzwfs model (dcuid=77)

h1lsc0:

Upgraded computer to fast 10 core machine

Added ADC card

modified h1ioplsc0 to reflect new IO Chassis hardware configuration

Added h1sqz model (dcuid=76)

h1sush56:

Added two 16bit-DAC cards

Modified h1susomc model to add OM1,2,3  (originally in h1sushtts)

Added new h1susopo model (dcuid=22) for VOPO, OFI, ZM1,2

Modified h1iopsush45 to reflect new IO Chassis hardware configuration

h1sush2b:

Added 16bit-DAC card

Added h1sushtts model (dcuid=21) for RM1,2

Modified h1iopsush2b to reflect new IO Chassis hardware configuration

h1susauxh56:

Added ADC card

Modified h1susauxh56 model, added SQZ aux channels

Modified h1iopsusauxh56 to reflect new IO Chassis hardware configuration

h1susauxh2:

Modified h1susauxh2 model to add RM1,2 aux channels