Reports until 13:37, Friday 27 October 2017
H1 CDS (SEI)
edmond.merilh@LIGO.ORG - posted 13:37, Friday 27 October 2017 (39185)
Corner Station H1 ISI Coil Drivers Updated

All Corner Station H1 ISI Coil Driver chassis were removed from their racks and modified in trhe EE lab as per ECRs E1100821 & E1300535 .   These mods also include the swapping of a wire on the temp reset switch from the "normally closed" position to the "normally open" position. Also, a number of the surface mount +15VDC indicator LEDs were installed incorrectly and would not illuminate.

Chassis S1103566 in SEI rack C1 doesn't have the "keyed" 24VDC connector. It has the typical +/- 18VDC config and associated power cable.

Chassis S1103363 (HAM2) in SEI rack C2 was noted as having a -15V led not illuminated. Upon further investigation it was found to have a bad 7915 regulator which is what E1300535 was implemented to prevent.

All chassis were re-installed and are powered up. SEI team was informed. E-travelers will be updated.