edmond.merilh@LIGO.ORG - posted 08:42, Monday 30 October 2017 (39202)
PSL Status Report - Weekly: FAMIS #7462

Laser Status:
SysStat is good
Front End Power is 35.89W (should be around 30 W)
HPO Output Power is 153.9W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 10 days, 18 hr 36 minutes (should be days/weeks)
Reflected power = 23.33Watts
Transmitted power = 48.29Watts
PowerSum = 71.62Watts.

FSS:
It has been locked for 0 days 4 hr and 47 min (should be days/weeks)
TPD[V] = 2.786V (min 0.9V)

ISS:
The diffracted power is around 2.7% (should be 3-5%)
Last saturation event was 5 days 23 hours and 10 minutes ago (should be days/weeks)

Possible Issues:
PMC reflected power is high

 

Displaying report 1-1 of 1.