PSL Weekly FAMIS Tasks (FAMIS 3674 & 8446)

This morning I completed the weekly PSL FAMIS tasks.

HPO Pump Diode Operating Current Adjust (FAMIS 8446)

With the ISS OFF, I adjusted the operating current of the HPO DBs, changes summarized in the below table.  A screenshot of the PSL Beckhoff main screen is attached for future reference, as usual.

  Operating Current (A)
Old New
DB1 51.1 51.3
DB2 53.5 53.7
DB3 53.5 53.7
DB4 53.5 53.7

DB operating temperatures remain unchanged.  The HPO is now outputting 155.1 W, and the ISS is back ON.  This completes FAMIS 8446.

PSL Power Watchdog Reset (FAMIS 3674)

I reset both PSL power watchdogs at 16:49 UTC (9:49 PDT).  This completes FAMIS 3674.