I've updated the BSC-ISI model in the repo and it is ready for installation. - HAM-ISI model is still pending (should be very soon).
Following requests from Jim, Sheila, et al, this change will update the BSC-ISI watchdog to make the ISI more robust during earthquakes. We have changed the model to increase the hold-the-damping-on-even-if-stuff-is-saturating time from 3 to 60 seconds.
The updated model is in the userapps repo at SVN revision 16398
Installation instructions and more technical details are in technical note T1700481.
The approved ECR is E1700367
and the FRS is 9309
I've not pulled work permits.
-Brian