All awtpman processes were restarted with the latest code.
New sus models were installed for MC1, MC3, PRM and PR3 on h1sush2a.
The crash of h1susim model was tracked to a missing ipcRfm=1 flag on h1iopsush2b. In the process we imported local modified files from LLO for:
and I imported l1susim.mdl to make the h1susim.mdl but reverted the ADC channel changes made on the l1 model.
I changed H1's SITEMAP.adl to add a second SUS pull down for the IM medm screens (copied the links from LLO).
For anyone new to the IM optics naming, here is a conversion table from old to new names
SM1 | IM1 |
PMMT1 | IM2 |
PMMT2 | IM3 |
SM2 | IM4 |
ISI models for HAM2 and HAM3 were changed to read out IPC error rates into EPICS channels. We are seeing errors on watchdog IPC channels but not on OPLEV QUAD channels which is confusing. This investigation will continue tomorrow.