FYI - Updated HAM-ISI model is also ready for installation at the sites

I've updated the HAM-ISI model in the repo and it is ready for installation - this continues the BSC update from last week, which Dave installed last Tuesday.

recall- This change will update the HAM-ISI watchdog to make the ISI more robust during earthquakes. We have changed the model to increase the hold-the-damping-on-even-if-stuff-is-saturating time from 3 to 60 seconds.

The updated model and watchdog medm screen is in the userapps repo at SVN revision 16422

Installation instructions and more technical details are in technical note T1700481.

The approved ECR is E1700367

and the FRS is 9309
 

I've not pulled work permits.

-Brian

Comments related to this report
david.barker@LIGO.ORG - 14:55, Monday 06 November 2017 (39300)

Jim has opened WP7206